Code: 531-00
Description: Fusing fan error
The fan motor lock (rotating state) signal is sampled 30 times at 100 ms intervals and the fan goes into an unstable rotating state at least ten times. (No error detection occurs for two seconds after the start of the fan or after changing the speed.)
The fan motor lock (rotating state) signal is sampled 30 times at 100 ms intervals and the fan goes into an unstable rotating state at least ten times. (No error detection occurs for two seconds after the start of the fan or after changing the speed.)
Causes: - Failed fan motor - Disconnected connector
Remedy: - Replace the fan motor. - Check the connector.