Code: 670-00
Description: Engine startup error
Case 1: • When the main power is turned on or when the machine is recovering from energy saver mode, the /ENGRDY signal assertion fails. • After the main power is turned on, the engine does not make the EC response within the specified time. • After the main power is turned on, the engine does not make the PC response within the specified time. • Writing of the Rapi driver failed (not recognized by PCI). Case 2: After the /ENGRDY signal assertion, an unintended shutdown is detected.
Case 1: • When the main power is turned on or when the machine is recovering from energy saver mode, the /ENGRDY signal assertion fails. • After the main power is turned on, the engine does not make the EC response within the specified time. • After the main power is turned on, the engine does not make the PC response within the specified time. • Writing of the Rapi driver failed (not recognized by PCI). Case 2: After the /ENGRDY signal assertion, an unintended shutdown is detected.
Causes: Case 1: • The Engine Board does not start up. Case 2: The Engine Board is reset at an unintended timing. Check the connection and the contact between the Engine Board and the Controller Board again. If the error is 100% reproducible, replace the Engine Board. If the error is still not resolved after the replacement, replace the Controller Board and junction boards.
Remedy: