Code: 672
Description: Controller startup error
• When communication between the controller and the operation panel does not begin normally after the machine is powered on or if communication is interrupted after a normal startup. • When the controller does not send an attention code (FDH) or attention acknowledge code (FEH) within 15 to 30 seconds after the operation panel is reset. • After the operation panel issues a command to check the communication line with the controller at 30-second intervals, the controller fails to respond twice.
• When communication between the controller and the operation panel does not begin normally after the machine is powered on or if communication is interrupted after a normal startup. • When the controller does not send an attention code (FDH) or attention acknowledge code (FEH) within 15 to 30 seconds after the operation panel is reset. • After the operation panel issues a command to check the communication line with the controller at 30-second intervals, the controller fails to respond twice.
Causes: 672-10 After the machine is powered on, communication (receiving) between the controller and operation panel is unable to begin normally. 672-11 After the machine is powered on, communication (sending) between the controller and operation panel is unable to begin normally, or data transmission after startup fails. 672-12 Communication with the controller is interrupted after a normal startup. 672-13 The operation panel detects that the controller is down for reasons other than those described above. 672-99 The software for the operation panel (OCS) is aborted.
Remedy: Turn the main switch off and on.