Code: 529
Description: Junction gate 1 motor error
The junction gate 1 HP sensor does not detect the home position of junction gate 1 for 0.15 seconds when the machine starts to detect its home position. The junction gate 1 HP sensor does not turn off for 0.15 seconds after the machine has detected its home position.
The junction gate 1 HP sensor does not detect the home position of junction gate 1 for 0.15 seconds when the machine starts to detect its home position. The junction gate 1 HP sensor does not turn off for 0.15 seconds after the machine has detected its home position.
Causes: • Disconnected or defective junction gate 1 motor • Disconnected or defective junction gate 1 HP sensor • Mechanical problem (such as paper jam etc.) • Shorted 24 V fuse on the PSU • Defective IOB
Remedy: 1. Remove any objects that obstruct junction gate 1. 2. Replace the junction gate 1 HP sensor. 3. Replace the junction gate 1 motor. 4. Replace the 24 V fuse on the PSU. 5. Replace the IOB.