Code: 498
Description: Temperature and humidity sensor error
• The thermistor output of the temperature sensor is not within the prescribed range (0.5V to 4.2V). If this is detected consecutively three times, the SC is generated and the machine defines that the temperature is "23°C". • The thermistor output of the humidity sensor is not within the prescribed range (0.01V to 2.4V). If this is detected consecutively three times, the SC is generated and the machine detects that the humidity is "50%".
• The thermistor output of the temperature sensor is not within the prescribed range (0.5V to 4.2V). If this is detected consecutively three times, the SC is generated and the machine defines that the temperature is "23°C". • The thermistor output of the humidity sensor is not within the prescribed range (0.01V to 2.4V). If this is detected consecutively three times, the SC is generated and the machine detects that the humidity is "50%".
Causes: • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective
Remedy: 1. Check the connector and harness. 2. Replace the temperature/humidity sensor.