Code: D200

Description: Detected that the modem PCB is not connected.
Remedy: 1 Modem PCB failure Replace the modem PCB ASSY. 2 Main PCB failure Replace the main PCB ASSY.

Code: D800

Description: An error occurred while initializing the touch panel.
Remedy: 1 Panel firmware version and main firmware version do not match Install the latest main firmware. 2 Connection failure of the panel flat cable Reconnect the panel flat cable. 3 LCD relay PCB failure Replace the LCD panel ASSY. 4 Main PCB failure Replace the main PCB ASSY.

Code: E000

Description: An error occurred in the ROM check sum.
Remedy: 1 Malfunction of the main firmware Install the latest main firmware. 2 Main PCB failure Replace the main PCB ASSY.

Code: E100

Description: Program error
Remedy: 1 Malfunction of the main firmware Install the latest main firmware. 2 Main PCB failure Replace the main PCB ASSY.

Code: E500

Description: An error occurred during access to the DRAM in the main PCB ASSY.
Remedy: 1 Malfunction of the main firmware Install the latest main firmware. 2 Main PCB failure Replace the main PCB ASSY.

Code: E600

Description: Write error in the EEPROM of the main PCB ASSY
Remedy: 1 Malfunction of the main firmware Install the latest main firmware. 2 Main PCB failure Replace the main PCB ASSY.

Code: E701

Description: System error in the flash ROM
Remedy: 1 Malfunction of the main firmware Install the latest main firmware. 2 Main PCB failure Replace the main PCB ASSY.

Code: E702

Description: Read error in the flash ROM
Remedy: 1 Malfunction of the main firmware Install the latest main firmware. 2 Main PCB failure Replace the main PCB ASSY.