Code :
- Code: B2
- Description: Gain control data level error for scanning. (Not used.)
- Causes:
- Remedy: CIS defective Replace the scanner cover (scanner unit). Main PCB defective Replace the main PCB.
- Code: B3
- Description: Scan area left edge detection error. (Not used.)
- Causes:
- Remedy: CIS defective Replace the scanner cover (scanner unit). White film stained in the scanner unit. Replace the scanner cover (scanner unit).
- Code: B4
- Description: Scan area right edge detection error. (Not used.)
- Causes:
- Remedy: CIS defective Replace the scanner cover (scanner unit). White film stained in the scanner unit. Replace the scanner cover (scanner unit).
- Code: B5
- Description: Horizontal scanning edge reduction detection error in scanning area setting (Not used.)
- Causes:
- Remedy:
- Code: B6
- Description: Horizontal scanning edge enlargement detection error in scanning area setting (Not used.)
- Causes:
- Remedy:
- Code: B7
- Description: A/D converter reference voltage error (at High level). (Not used.)
- Causes: Main PCB defective
- Remedy: Replace the main PCB.
- Code: B8
- Description: A/D converter reference voltage error (at Low level). (Not used.)
- Causes: Main PCB defective
- Remedy: Replace the main PCB.
- Code: B9
- Description: Light emission intensity error of the LED array (Exceeding the upper limit).
CIS defective Main PCB defective
- Causes:
- Remedy: CIS defective Replace the scanner cover (scanner unit). Main PCB defective Replace the main PCB.