Description: 50% or more faulty of white level data. (Not used.)
Causes:
Remedy: CIS flat cable not connected properly Correct the connection. CIS defective Replace the scanner cover (scanner unit). Main PCB defective Replace the main PCB.
Remedy: CIS defective White-level reference film stained in the scanner cover Replace the scanner cover (scanner unit). Main PCB defective Replace the main PCB.
Remedy: CIS defective White-level reference film stained in the scanner cover Replace the scanner cover (scanner unit). Main PCB defective Replace the main PCB.
Remedy: CIS flat cable broken or not connected Correct the cable connection. Replace the scanner cover (scanner unit). CIS motor harness not connected properly Correct the harness connection. CIS defective Replace the scanner cover (scanner unit). Main PCB defective Replace the main PCB.