Code: B2

Description: Gain control data level error for scanning. (Not used.)
Causes:
Remedy: CIS defective Replace the scanner cover (scanner unit). Main PCB defective Replace the main PCB.

Code: B3

Description: Scan area left edge detection error. (Not used.)
Causes:
Remedy: CIS defective Replace the scanner cover (scanner unit). White film stained in the scanner unit. Replace the scanner cover (scanner unit).

Code: B4

Description: Scan area right edge detection error. (Not used.)
Causes:
Remedy: CIS defective Replace the scanner cover (scanner unit). White film stained in the scanner unit. Replace the scanner cover (scanner unit).

Code: B5

Description: Horizontal scanning edge reduction detection error in scanning area setting (Not used.)
Causes:
Remedy:

Code: B6

Description: Horizontal scanning edge enlargement detection error in scanning area setting (Not used.)
Causes:
Remedy:

Code: B7

Description: A/D converter reference voltage error (at High level). (Not used.)
Causes: Main PCB defective
Remedy: Replace the main PCB.

Code: B8

Description: A/D converter reference voltage error (at Low level). (Not used.)
Causes: Main PCB defective
Remedy: Replace the main PCB.

Code: B9

Description: Light emission intensity error of the LED array (Exceeding the upper limit).
CIS defective Main PCB defective
Causes:
Remedy: CIS defective Replace the scanner cover (scanner unit). Main PCB defective Replace the main PCB.