Description: Harness for scanning is not connected correctly.
Causes:
Remedy: 1 Scanner harness not connected correctly. Reconnect the scanner harness correctly. 2 Scanner harness broken Replace the FB unit. 3 Main PCB failure Replace the main PCB ASSY.
Code: B7
Description: Detection error of scanner (Scanning reference voltage adjustment malfunction.)
Causes:
Remedy: 1 FB unit failure Replace the FB unit. 2 Main PCB failure Replace the main PCB ASSY.
Code: B9
Description: Scanning light adjustment error.
Causes:
Remedy: 1 FB unit failure Replace the FB unit. 2 Main PCB failure Replace the main PCB ASSY.
Code: BB
Description: White level data error
Causes:
Remedy: 1 FB unit failure Replace the FB unit. 2 Main PCB failure Replace the main PCB ASSY.
Code: E6
Description: NVRAM error on main PCB
Causes:
Remedy: 1 Main PCB failure Replace the main PCB ASSY.
Code: EC
Description: Fan performance malfunction
Causes:
Remedy: 1 Harness connection failure of fan motor Check the harness connection of the fan motor, and reconnect it. 2 Fan motor failure Replace the fan motor. 3 Main PCB failure Replace the main PCB ASSY.
Code: F8
Description: Battery connection failure
Causes:
Remedy: 1 Battery harness connection failure Reconnect the battery harness. 2 Battery exhausted Replace the battery. 3 Main PCB failure Replace the main PCB ASSY.
Code: F9
Description: Maintenance mode 74 Non-decision (Inputting omission of the customizing code.)
Causes:
Remedy: 1 Turn the power off, when the Maintenance mode 74 is in progress. Implement the Maintenance mode 74 again.