Description: Fuser unit error. (The center thermistor detects 60°C or lower temperature for 1 second during standby or printing.)
Causes:
Remedy: 1 Fuser unit connector connection failure Check the connector connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 Low voltage power supply PCB failure Replace the low voltage power supply PCB ASSY. 4 Paper eject sensor PCB failure Replace the paper eject sensor PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.
Description: Fuser unit error. (The center and side thermistors detect extremely high temperature.) (Detection of hardware)
Causes:
Remedy: 1 Fuser unit connector connection failure Check the connector connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 Low voltage power supply PCB failure Replace the low voltage power supply PCB ASSY. 4 Paper eject sensor PCB failure Replace the paper eject sensor PCB ASSY. 5 Main PCB failure Replace the main PCB ASSY.
Remedy: 1 Correction value error of laser unit Input the correction value of the laser unit correctly. 2 Harness connection failure of laser unit Check the harness connection of the laser unit and reconnect them. 3 Main PCB failure Replace the main PCB ASSY. 4 Laser unit failure Replace the laser unit.
Description: Beam detecting sensor error of the laser unit.
Causes:
Remedy: 1 Correction value error of laser unit Input the correction value of the laser unit correctly. 2 Harness connection failure of laser unit Check the harness connection of the laser unit and reconnect them. 3 Main PCB failure Replace the main PCB ASSY. 4 Laser unit failure Replace the laser unit.
Description: Fuser unit error. (The center thermistor detects the sharp temperature rise.)
Causes:
Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Low voltage power supply PCB failure Replace the low voltage power supply PCB ASSY. 3 Paper eject sensor PCB failure Replace the paper eject sensor PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.
Description: Fuser unit error. (The center thermistor detects the sharp temperature fall.)
Causes:
Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Low voltage power supply PCB failure Replace the low voltage power supply PCB ASSY. 3 Paper eject sensor PCB failure Replace the paper eject sensor PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.