Các lỗi thường gặp

Code :
  • Code: 68
  • Description: Fuser unit failure
    (The side thermistor detects higher temperature than the specified value.)
  • Causes:
  • Remedy: 1 Fuser unit harness connection failure Check the harness connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 LVPS PCB unit failure Replace the LVPS PCB unit. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 69
  • Description: Fuser unit failure
    (The side thermistor detects lower temperature than the specified value.)
  • Causes:
  • Remedy: 1 Fuser unit harness connection failure Check the harness connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 LVPS PCB unit failure Replace the LVPS PCB unit. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 6A
  • Description: Fuser unit failure
    (The side thermistor does not detect 60°C within the specified time.)
  • Causes:
  • Remedy: 1 Fuser unit harness connection failure Check the harness connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 LVPS PCB unit failure Replace the LVPS PCB unit. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 6B
  • Description: Fuser unit failure
    (The center thermistor does not detect 100°C within the specified time.)
  • Causes:
  • Remedy: 1 Fuser unit harness connection failure Check the harness connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 LVPS PCB unit failure Replace the LVPS PCB unit. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 6C
  • Description: Fuser unit failure
    (The center thermistor detects higher temperature than the specified value.)
  • Causes:
  • Remedy: 1 Fuser unit harness connection failure Check the harness connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 LVPS PCB unit failure Replace the LVPS PCB unit. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 6D
  • Description: Fuser unit failure
    (The center thermistor detects lower temperature than the specified value.)
  • Causes:
  • Remedy: 1 Fuser unit harness connection failure Check the harness connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 LVPS PCB unit failure Replace the LVPS PCB unit. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 6E
  • Description: Fuser unit failure
    (The center thermistor does not detect temperature rising within the specified time.)
  • Causes:
  • Remedy: 1 Fuser unit harness connection failure Check the harness connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 LVPS PCB unit failure Replace the LVPS PCB unit. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 6F
  • Description: Fuser unit failure
    (The center and side thermistors detect extremely high temperature.)
  • Causes:
  • Remedy: 1 Fuser unit harness connection failure Check the harness connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit. 3 LVPS PCB unit failure Replace the LVPS PCB unit. 4 Main PCB failure Replace the main PCB ASSY.