Code: 5E

Description: MP tray sensor remains OFF.
Causes: • MP tray sensor

Code: 5F

Description: DX unit sensor is inactivated.
Causes: • DX unit sensor

Code: 6A

Description: Heater warming-up timeout error. (Heater does not reach 60°C within 11 sec.)
Causes: • Thermistor ASSY • Halogen lamp

Code: 6B

Description: Heater warming-up timeout error. (Heater does not reach 100°C within 15 sec.)
Causes: • Thermistor ASSY • Halogen lamp

Code: 6C

Description: Heater temperature exceeds the maximum high temperature. (270°C or more is detected for 1 sec.)
Causes: • Thermistor ASSY • Power supply PCB

Code: 6D

Description: Heater temperature lowers the minimum low temperature. (60°C or less is detected for 1 sec.)
Causes: • Thermistor ASSY • Power supply PCB

Code: 6E

Description: Heater temperature does not go up enough. (Slower temperature rise rate than 2°C/5 sec. is detected.)
Causes: • Halogen lamp • Power supply PCB

Code: 6F

Description: Heater hard limiter operates.
Causes: • Thermistor ASSY • Power supply PCB