Code :
- Code: 5E
- Description: MP tray sensor remains OFF.
- Causes: • MP tray sensor
- Code: 5F
- Description: DX unit sensor is inactivated.
- Causes: • DX unit sensor
- Code: 6A
- Description: Heater warming-up timeout error. (Heater does not reach 60°C within 11 sec.)
- Causes: • Thermistor ASSY • Halogen lamp
- Code: 6B
- Description: Heater warming-up timeout error. (Heater does not reach 100°C within 15 sec.)
- Causes: • Thermistor ASSY • Halogen lamp
- Code: 6C
- Description: Heater temperature exceeds the maximum high temperature. (270°C or more is detected for 1 sec.)
- Causes: • Thermistor ASSY • Power supply PCB
- Code: 6D
- Description: Heater temperature lowers the minimum low temperature. (60°C or less is detected for 1 sec.)
- Causes: • Thermistor ASSY • Power supply PCB
- Code: 6E
- Description: Heater temperature does not go up enough. (Slower temperature rise rate than 2°C/5 sec. is detected.)
- Causes: • Halogen lamp • Power supply PCB
- Code: 6F
- Description: Heater hard limiter operates.
- Causes: • Thermistor ASSY • Power supply PCB