Causes: • Close the back cover. • Install the Duplex unit.
Remedy: 1 Harness connection failure of relay rear PCB ASSY. Check the harness connection of the relay rear PCB ASSY and reconnect it. 2 Relay rear PCB ASSY failure Replace the relay rear PCB ASSY. 3 Main PCB failure Replace the main PCB ASSY.
Code: 57
Description: Paper jam (Duplex tray)
Causes:
Remedy: 1 Duplex feed ASSY failure Replace the X feed ASSY. 2 Main PCB failure Replace the main PCB ASSY. 3 Plate gear damaged Replace the main frame L unit.
Code: 58
Description: Fuser unit failure
Causes:
Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Main PCB failure Replace the main PCB ASSY.
Code: 59
Description: Fuser unit failure (Detect fuser failure at start-up)
Causes:
Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Main PCB failure Replace the main PCB ASSY.
Code: 63
Description: Toner life end
Causes: • Replace the toner cartridge with a new one.
Remedy: 1 Relay front PCB ASSY failure Replace the relay front PCB ASSY. 2 Main PCB failure Replace the main PCB ASSY.
Code: 67
Description: Toner low
Causes: • Prepare the toner cartridge with a new one.
Remedy: 1 Toner sensor PCB ASSY failure Replace the toner sensor PCB ASSY. 2 Main PCB failure Replace the main PCB ASSY.
Code: 68
Description: Temperature rise when heater is off
Causes:
Remedy: 1 Fuser unit failure Replace the fuser unit 2 Main PCB failure Replace the main PCB ASSY.
Code: 69
Description: Mis-connect center thermistor connector
Causes:
Remedy: 1 Harness connection failure of fuser unit. Check the harness connection of fuser unit and reconnect it. 2 Harness connection failure of relay rear PCB ASSY. Check the harness connection of the relay rear PCB ASSY and reconnect it. 3 Fuser unit failure Replace the fuser unit 4 Main PCB failure Replace the main PCB ASSY.