Description: There was no response from the panel PCB for the specified time after initializing the panel PCB.
Remedy: <User Check> • Install the latest firmwares (panel firmware and main firmware). 1 Touch panel failure Replace the touch panel ASSY. 2 Main PCB failure Replace the main PCB ASSY.
Code: E000
Display: Print Unable E0 Turn the power off and then back on again.
Description: An error occurred in the ROM check sum.
Remedy: <User Check> • Install the latest firmware. 1 Main PCB failure Replace the main PCB ASSY.
Code: E100
Display: Print Unable E1 Turn the power off and then back on again.
Description: Program error
Remedy: <User Check> • Install the latest firmware. 1 Main PCB failure Replace the main PCB ASSY.
Code: E500
Display: Print Unable E5 Turn the power off and then back on again.
Description: An error occurred during access to the DRAM in the main PCB ASSY.
Remedy: 1 Main PCB failure Replace the main PCB ASSY.
Code: E600
Display: Print Unable E6 Turn the power off and then back on again.
Description: Write error in the EEPROM of the main PCB ASSY
Remedy: 1 Main PCB failure Replace the main PCB ASSY.
Code: E701
Display: Print Unable E7 Turn the power off and then back on again.
Description: Irregular operation of the flash ROM file system on the main PCB.
Remedy: 1 Main PCB failure Replace the main PCB ASSY.
Code: E702
Display: Print Unable E7 Turn the power off and then back on again.
Description: Read error in the flash ROM on the main PCB
Remedy: 1 Main PCB failure Replace the main PCB ASSY.
Code: F900
Display: Machine Error F9
Description: The country code was not entered correctly.
Remedy: 1 The power was turned OFF while function code 74 was running. Reenter the country code. 2 Main PCB failure Replace the main PCB ASSY.