Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Brother MFC3200C — Trang 3/7

Code: 47

Description: Head parameters stored in the EEPROM are invalid. (This code may appear only in the maintenance mode.)
Causes: • Print head unit • Main PCB • Power supply PCB

Code: 48

Description: Weak connection of the head flat cables.
Causes: • Head flat cables • Main PCB

Code: 4D

Description: Error in the head drive voltage parameter stored in the EEPROM but not accessible at the user site. (This code may appear only in the maintenance mode.)
Causes: • Main PCB

Code: 4E

Description: Out of the allowable range of the head drive voltage designed for individual print head properties. (This code may appear only in the maintenance mode.)
Causes: • Main PCB • Print head unit

Code: 50

Description: The purge cam HP switch does not come ON even after the purge cam has been driven by the specified number of pulses.
Causes: • Purge unit • Purge-related gears on the main chassis (Purge bevel gear A, ASF/purge idle gear, and ASF-purge switching gear 23) • Main chassis • Paper feed motor • Main PCB

Code: 51

Description: The purge cam HP switch does not go OFF even after the purge cam has been driven by the specified number of pulses.
Causes:

Code: 52

Description: The pump switching cam HP switch does not come ON even after the switching cam has been driven by the specified number of pulses.
Causes:

Code: 53

Description: The pump switching cam HP switch does not go OFF even after the switching cam has been driven by the specified number of pulses.
Causes:
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie