Description: Polygon motor failure (Cannot detect the period signal of the polygon mirror motor.)
Causes:
Remedy: 1 Laser unit harness connection failure Check the two harness connections of the laser unit and reconnect them. 2 Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.
Causes: Laser unit harness connection failure. Laser unit failure. Main PCB failure
Remedy: 1 Laser unit harness connection failure Check the two harness connections of the laser unit and reconnect them. 2 Laser unit failure Replace the laser unit. 3 Main PCB failure Replace the main PCB ASSY.
Causes: The temperature inside the machine is too high. Both ends of the heat roller are at different temperatures. The paper media is replaced with different Paper size media.
Remedy: • After having passed for a while with having turned the power supply on.
Description: Fuser unit failure (The center thermistor detects rapidly rising temperature.)
Causes:
Remedy: 1 Fuser unit harness connection failure Check the harness connection of the fuser unit and reconnect it. 2 Fuser unit failure Replace the fuser unit.
Description: No detection of the internal temperature thermistor
Causes: Harness connection failure of internal temperature thermistor Internal temperature thermistor failure Main PCB failure