Các lỗi thường gặp

Code :
  • Code: 7A
  • Description: A lock signal of the main motor cannot be detected.
  • Causes:
  • Remedy: 1 Flat cable connection failure of main motor Check the flat cable connection of the main motor and reconnect them. 2 Main motor failure Replace the main motor. 3 Low voltage power supply PCB failure Replace the low voltage power supply PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.
  • Code: 7B
  • Description: An unidentified error occurred.
  • Causes: Main PCB failure
  • Remedy: Replace the main PCB ASSY.
  • Code: 7C
  • Description: An unidentified error occurred.
  • Causes: Main PCB failure
  • Remedy: Replace the main PCB ASSY.
  • Code: 7D
  • Description: Dirt on drum unit.
  • Causes: • Clean the corona wire of drum unit. • Turn OFF the power switch, and turn it ON again after a while.
  • Remedy: 1 Dirt on the electrode of the drum unit and on the machine Clean the dirt on the contact points of the both electrodes. (Refer to Fig. 2-11, Fig. 2-12) 2 High voltage power supply PCB failure Replace the high voltage power supply PCB ASSY. 3 Main PCB failure Replace the main PCB ASSY.
  • Code: 7E
  • Description: An unidentified error occurred.
  • Causes: Main PCB failure
  • Remedy: Replace the main PCB ASSY.
  • Code: 7F
  • Description: FAX paper size is incorrect. (Menu setting)
  • Causes: 1 Main PCB failure
  • Remedy: Replace the main PCB ASSY.
  • Code: 80
  • Description: FAX paper size is incorrect. (The actually loaded paper is small)
  • Causes: 1 Main PCB failure
  • Remedy: Replace the main PCB ASSY.
  • Code: 83
  • Description: Drum unit error (An drum error occurred after the drum unit reached the end of life.)
  • Causes: 1 Main PCB failure
  • Remedy: Replace the main PCB ASSY.