Code: 46

Description: The number of performed purge sequences has reached the limit.

Code: 4B

Description: Abnormal carriage travel speed detected when the power was applied.

Code: 4C

Description: Head rated voltage data stored in the EEPROM on the head PCB is invalid. (This code may appear only in the maintenance mode.)

Code: 50

Description: The purge cam HP switch does not come ON even after the purge cam has been driven by the specified number of
pulses.

Code: 51

Description: The purge cam HP switch does not go OFF even after the purge cam has been driven by the specified number of
pulses.

Code: 52

Description: At the time of purge operation, the carriage has not stopped in the purge position.

Code: 53

Description: The purge cam HP switch has come ON when the carriage was in the wipe position.

Code: 54

Description: When reset, the purge cam HP switch does not come ON even after the purge cam has been driven by the specified
number of pulses.