Code :
  • Code: 71
  • Description: Scanner motor does not synchronize with the reference clock.
  • Causes: • Scanner motor
  • Code: 72
  • Description: Cannot detect Beam Detect signal.
  • Causes: • Scanner motor
  • Code: 73
  • Description: Drum unit is not mounted.
  • Causes: • Toner sensor • Drum unit
  • Code: 74
  • Description: Toner empty.
  • Causes: • Toner sensor • Toner cartridge
  • Code: 75
  • Description: In-casing temperature error.
  • Causes: • Thermistor ASSY
  • Code: 76
  • Description: Heater harness disconnected or broken.
  • Causes: • Thermistor ASSY • Halogen lamp
  • Code: 77
  • Description: Power was turned off when error 76 or error 78 occurred.
  • Causes:
  • Code: 78
  • Description: Heater thermistor harness disconnected or broken.
  • Causes: • Thermistor ASSY