Description: Central temperature of heat roller detected the temperature that was lower than 60°C)
Causes: 1 Relay rear PCB ASSY connection failure. 2 Fuser unit failure. 3 Main PCB failure.
Remedy: 1 Relay rear PCB ASSY connection failure Reconnect the relay rear PCB ASSY connector correctly. 2 Fuser unit failure Replace the fuser unit. 3 Main PCB failure Replace the main PCB ASSY.
Code: E0
Description: Program error
Causes: 1 Program failure. 2 Main PCB failure
Remedy: 1 Program failure Reinstall the latest firmware. 2 Main PCB failure Replace the main PCB ASSY.
Code: E1
Description: Main PCB failure
Causes: 1 Main PCB failure
Remedy: Replace the main PCB ASSY.
Code: E2
Description: Central temperature of heat roller exceeds 280°C
Causes: 1 Fuser unit failure. 2 Main PCB failure
Remedy: 1 Fuser unit failure Replace the fuser unit. 2 Main PCB failure Replace the main PCB ASSY.
Code: E6
Description: EEPROM error
Causes: 1 Main PCB failure
Remedy: Replace the main PCB ASSY.
Code: EB
Description: The data reading error for E2PROM
Causes: 1 Main PCB failure
Remedy: Replace the main PCB ASSY.
Code: EC
Description: Fuser fan failure
Causes: 1 Main fan failure. 2 Main PCB failure
Remedy: 1 Main fan failure Replace the main fan ASSY. 2 Main PCB failure Replace the main PCB ASSY.
Code: ED
Description: Wireless LAN connection failure between W-LAN PCB and access point
Causes: 1 WLAN PCB failure. 2 Main PCB failure
Remedy: 1 WLAN PCB failure Replace the WLAN PCB ASSY. 2 Main PCB failure Replace the main PCB ASSY.