Description: The back cover sensor detected that the cover was open in duplex printing mode.
Causes: 1 Connection failure of the back cover sensor harness. 2 Back cover sensor attachment failure. 3 Broken rib (on the right inside the back cover) where the back cover switch is pressed. 4 Damaged duplex tray. 5 Back cover sensor failure. 6 Main PCB failure
Remedy: 1 Connection failure of the back cover sensor harness Check the connection of the back cover sensor harness, and reconnect it if necessary. 2 Back cover sensor attachment failure Reattach the back cover sensor. 3 Broken rib (on the right inside the back cover) where the back cover switch is pressed Replace the back cover. 4 Damaged duplex tray Replace the duplex tray. 5 Back cover sensor failure Replace the back cover switch harness ASSY. 6 Main PCB failure Replace the main PCB ASSY.
Description: The toner sensor detected that the toner cartridge was not set.
Causes: 1 Toner sensor PCB failure. 2 Relay front PCB failure. 3 Main PCB failure
Remedy: 1 Toner sensor PCB failure Refer to "1.3.10 Check sensor operation (function code: 32)" in Chapter 5 to check the sensor operation. If the sensor operation is faulty, replace the toner sensor PCB ASSY. 2 Relay front PCB failure Replace the relay front PCB ASSY. 3 Main PCB failure Replace the main PCB ASSY.