Mã lỗi Brother MFC8710DW

Code: 0B00

Description: There was no response from the panel for the specified time for any reason.
Causes: 1 Panel PCB failure. 2 Touch panel PCB failure. 3 Main PCB failure
Remedy: 1 Panel PCB failure Replace the panel PCB ASSY. 2 Touch panel PCB failure Replace the touch panel PCB ASSY. 3 Main PCB failure Replace the main PCB ASSY.

Code: 0C01, 0C02, 0C03, 0C04

Description: Log registration failed.
Causes: 1 Main PCB failure
Remedy: Replace the main PCB ASSY.

Code: 0E00

Description: Communication between the panel PCB and the main PCB cannot be established at machine startup.
Causes: 1 Connection failure of the panel PCB harness. 2 Panel PCB failure. 3 Touch panel PCB failure. 4 Main PCB failure.
Remedy: 1 Connection failure of the panel PCB harness Reconnect the panel PCB harness. 2 Panel PCB failure Replace the panel PCB ASSY. 3 Touch panel PCB failure Replace the touch panel PCB ASSY. 4 Main PCB failure Replace the main PCB ASSY.

Code: 0F00

Description: The back cover sensor detected that the cover was open in duplex printing mode.
Causes: 1 Connection failure of the back cover sensor harness. 2 Back cover sensor attachment failure. 3 Broken rib (on the right inside the back cover) where the back cover switch is pressed. 4 Damaged duplex tray. 5 Back cover sensor failure. 6 Main PCB failure
Remedy: 1 Connection failure of the back cover sensor harness Check the connection of the back cover sensor harness, and reconnect it if necessary. 2 Back cover sensor attachment failure Reattach the back cover sensor. 3 Broken rib (on the right inside the back cover) where the back cover switch is pressed Replace the back cover. 4 Damaged duplex tray Replace the duplex tray. 5 Back cover sensor failure Replace the back cover switch harness ASSY. 6 Main PCB failure Replace the main PCB ASSY.

Code: 3600

Description: An error occurred in the high-voltage power supply PCB.
Causes: 1 High-voltage power supply PCB failure. 2 Main PCB failure
Remedy: 1 High-voltage power supply PCB failure Replace the high-voltage power supply PCB ASSY. 2 Main PCB failure Replace the main PCB ASSY.

Code: 3B00

Description: An error occurred during access to the DRAM in the main PCB.
Causes: 1 Main PCB failure
Remedy: Replace the main PCB ASSY.

Code: 4400

Description: The toner sensor detected that the toner cartridge was not set.
Causes: 1 Toner sensor PCB failure. 2 Relay front PCB failure. 3 Main PCB failure
Remedy: 1 Toner sensor PCB failure Refer to "1.3.10 Check sensor operation (function code: 32)" in Chapter 5 to check the sensor operation. If the sensor operation is faulty, replace the toner sensor PCB ASSY. 2 Relay front PCB failure Replace the relay front PCB ASSY. 3 Main PCB failure Replace the main PCB ASSY.

Code: 5000

Description: The number of rotations of the drum unit has reached the life limit. (Printing does not stop.)
Causes: 1 Replace the drum unit with a new one and reset the drum counter. If the error display is not cleared, the main PCB is faulty.
Remedy: Replace the main PCB ASSY.