Code: AC00

Description: When scanning the fax, white or black correction data for the second side CIS was not within the correct range.
Causes: 1 Second side CIS unit failure. 2 Main PCB failure.
Remedy: 1 Second side CIS unit failure Replace the second side CIS unit. 2 Main PCB failure Replace the main PCB ASSY.

Code: AD00

Description: Image processing cannot be completed correctly because the number of pixels required for image processing is insufficient in the scanned data for the front side of the document.
Causes: 1 Incorrect correction data for first side CIS. 2 First side CIS unit failure. 3 Main PCB failure.
Remedy: 1 Incorrect correction data for first side CIS Execute function code 55. 2 First side CIS unit failure Replace the first side CIS unit. 3 Main PCB failure Replace the main PCB ASSY.

Code: AF00

Description: Home position is still being detected even after the first side CIS for the document scanner unit was moved.
Causes: 1 CIS drive belt coming off. 2 First side CIS unit failure. 3 Document scanner motor failure. 4 Main PCB failure.
Remedy: 1 CIS drive belt coming off Reattach the CIS drive belt. 2 First side CIS unit failure Replace the first side CIS unit. 3 Document scanner motor failure Replace the document scanner unit. 4 Main PCB failure Replace the main PCB ASSY.

Code: B000

Description: Detected that the first side CIS flat cable or second side CIS flat cable was not inserted correctly.
Causes: 1 Connection failure of the first side CIS flat cable or second side CIS flat cable. 2 First side CIS unit or second side CIS unit failure. 3 Main PCB failure.
Remedy: 1 Connection failure of the first side CIS flat cable or second side CIS flat cable Reconnect the first side CIS flat cable or second side CIS flat cable. 2 First side CIS unit or second side CIS unit failure Replace the first side CIS unit or second side CIS unit. 3 Main PCB failure Replace the main PCB ASSY.

Code: B700

Description: The voltage value was above the upper limit during scanning.
Causes: 1 First side CIS unit or second side CIS unit failure. 2 Main PCB failure.
Remedy: 1 First side CIS unit or second side CIS unit failure Replace the first side CIS unit or second side CIS unit. 2 Main PCB failure Replace the main PCB ASSY.

Code: B800

Description: The voltage value was below the lower limit during scanning.
Causes: 1 First side CIS unit or second side CIS unit failure. 2 Main PCB failure.
Remedy: 1 First side CIS unit or second side CIS unit failure Replace the first side CIS unit or second side CIS unit. 2 Main PCB failure Replace the main PCB ASSY.

Code: B900

Description: The white level does not increase during scanning although the light intensity was increased.
Causes: 1 First side CIS unit or second side CIS unit failure. 2 Main PCB failure.
Remedy: 1 First side CIS unit or second side CIS unit failure Replace the first side CIS unit or second side CIS unit. 2 Main PCB failure Replace the main PCB ASSY.

Code: BB00

Description: A white level not within the standard was scanned when function code 55 was executed.
Causes: 1 First side CIS unit or second side CIS unit failure. 2 Main PCB failure.
Remedy: 1 First side CIS unit or second side CIS unit failure Replace the first side CIS unit or second side CIS unit. 2 Main PCB failure Replace the main PCB ASSY.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie