Mã lỗi Brother MFC890 — Trang 3/8

Code: 47

Description: Head parameters stored in the EEPROM are invalid. (This code may appear only in the maintenance mode.)
Causes: • Print head unit •Main PCB • Power supply PCB • Driver PCB

Code: 48

Description: Weak connection of the head flat cable M (main-head power line).or W (driver-head signal line)
Causes: • Main PCB • Head flat cable M • Driver PCB • Head flat cable W • Print head unit

Code: 4D

Description: Error in the head drive voltage parameter stored in the EEPROM but not accessible at the user site. (This code may appear only in the maintenance mode.)
Causes: • Driver PCB

Code: 4E

Description: Out of the allowable range of the head drive voltage designed for individual print head properties. (This code may appear only in the maintenance mode.)
Causes: • Driver PCB

Code: 50

Description: The purge cam HP switch does not come ON even after the purge cam has been driven by the specified number of pulses.
Causes: • Purge unit • Purge-related gears on the main chassis (Purge bevel gear A, ASF/purge idle gear, and ASF-purge switching gear 23) • Main chassis • Paper feed motor •Main PCB • Driver PCB

Code: 51

Description: The purge cam HP switch does not go OFF even after the purge cam has been driven by the specified number of pulses.
Causes:

Code: 52

Description: The pump switching cam HP switch does not come ON even after the switching cam has been driven by the specified number of pulses.
Causes:

Code: 53

Description: The pump switching cam HP switch does not go OFF even after the switching cam has been driven by the specified number of pulses.
Causes: