Các lỗi thường gặp

Code :
  • Code: E007-0101
  • Description: Fixing belt or pressure belt deviation trouble
    Fixing belt home position detection error
  • Remedy: Replace the fixing belt HP sensor. Replace the fixing deviation control motor, DC controller PCB 2 (MAISY) and fixing unit.
  • Code: E007-0102
  • Description: Fixing belt or pressure belt deviation trouble
    Pressure belt home position detection error
  • Remedy: Replace the pressure belt HP sensor. Replace the pressure deviation control motor, DC controller PCB 2 (MAISY) and fixing unit.
  • Code: E007-0201
  • Description: Fixing belt or pressure belt deviation trouble
    Belt push-off temporary escape mode error
  • Remedy: Occurs when the belt deviation is not eliminated within 1 minute in the belt push-off temporary escape mode.
  • Code: E007-9991
  • Description: Fixing belt or pressure belt deviation trouble
    Top belt deviation control timeout error
  • Remedy: Occurs when operation was not performed normally when COPIER > FUNCTION > FIXING > FX-UHP-S was executed.
  • Code: E007-9992
  • Description: Fixing belt or pressure belt deviation trouble
    Bottom belt deviation control timeout error
  • Remedy: Occurs when operation was not performed normally when COPIER > FUNCTION > FIXING > FX-LHP-S was executed.
  • Code: E008-0001
  • Description: Fixing unit end-of-life detection error
    Fixing unit end-of-life detection error
  • Remedy: Occurs when the fixing unit end-of-life is detected or when the belt pushoff temporary escape mode was executed but normal operation was not restored.
  • Code: E009-0500
  • Description: Pressure belt pressure release error
    Pressure belt unit pressure release HP search error
  • Remedy: Replace the fixing pressure release HP sensor. Replace the fixing pressure motor. Replace the DC controller PCB 2 (MAISY).
  • Code: E009-0501
  • Description: Pressure belt pressure release error
    Pressure belt unit pressure release timeout error
  • Remedy: Replace the fixing pressure release HP sensor. Replace the fixing pressure motor. Replace the DC controller PCB 2 (MAISY).