Causes: The CIS Unit did not move to HP even it moved backward. Reader HP Sensor error, Reader Motor error, CIS Unit error
Remedy: 1. Replace the Reader HP Sensor. 2. Replace the Reader Motor. 3. Replace the CIS Unit. 4. Replace the Reader Unit.
Code: E202-0002
Description: CIS Unit HP error (homeward)
Causes: The CIS Unit did not move to HP even it moved forward. Reader HP Sensor error, Reader Motor error, CIS Unit error
Remedy: 1. Replace the Reader HP Sensor. 2. Replace the Reader Motor. 3. Replace the CIS Unit. 4. Replace the Reader Unit.
Code: E246-0000
Description: System error
Causes: System error
Remedy: Contact the sales company.
Code: E247-0000
Description: System error
Causes: System error
Remedy: Contact the sales company.
Code: E302-0001
Description: Shading error
Causes: When the light intensity is below the reference level at shading
Remedy: 1. Disconnect and then connect the Flexible Cable. 2. Replace the Flexible Cable. 3. Replace the CIS Unit. 4. Replace the Main Controller PCB (PCB2).
Code: E302-0002
Description: Shading error
Causes: Image sampling for shading was not completed.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the harness. 3. Replace the Main Controller PCB. 4. Replace the Reader Unit.