Description: Card Reader communication error (serial communication)
Causes: Communication with the Card Reader could not be started at startup.
Remedy: 1. After turning OFF the power, check the connection of the Card Reader-F1 and the short connector [A], and turn ON the power 2. After turning OFF the power, replace the cable included in the package of the Card Reader-F1 or the Copy Card Reader Attachment-J1, and turn ON the power.
Remedy: 1. Check the connector connection between the Engine Controller PCB and the Main Controller PCB. 2. Install the set of the controller firmware. 3. Replace the Main Controller PCB. 4. Replace the Engine Controller PCB.
Causes: Communication error between the Engine Controller PCB and the Main Controller PCB occurred.
Remedy: 1. Check the connector connection between the Engine Controller PCB and the Main Controller PCB. 2. Install the set of the controller firmware. 3. Replace the Main Controller PCB. 4. Replace the Engine Controller PCB.