Description: CIS Unit HP error (homeward)
CIS Unit did not move to HP even it moved forward.
Reader HP Sensor error, Reader Motor error, CIS Unit error
Remedy: 1. Replace the Reader HP Sensor. 2. Replace the Reader Motor. 3. Replace the CIS Unit. 4. Replace the Reader Unit.
Description: Error in access to backup data for Reader (reading error at power-on)
The Reader-related adjustment values could not be read.
Remedy: 1. Clear the backup RAM of RCON. Execute COPIER>FUNCTION>CLEAR>RCON. 2. Enter all the values written on the service label in service mode again. 3. Turn OFF and then ON the main power.
Description: Printer communication error
Communication error between the Engine Controller PCB and the Main Controller PCB occurred.
Remedy: 1. Check the connection of connector between the Engine Controller PCB and the Main Controller PCB. 2. Install the set of the controller firmware. 3. Replace the Main Controller PCB. 4. Replace the Engine Controller PCB.