Causes: After the fixing heater has gone on, the reading is not -5 deg C of the target temperature within 75 sec. Cause The fixing film unit is faulty. The engine controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the engine controller PCB.
Causes: After the fixing heater has gone on, the reading of the main thermistor is not 50 deg C within about 1.5 sec. Cause The fixing film unit is faulty. The engine controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the engine controller PCB.
Causes: A temperature of the main thermistor is detected 240 degrees Celsius for one second. Cause The main thermistor is faulty. The engine controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the engine controller PCB.
Causes: A temperature of the sub-thermistor is detected 320 degrees Celsius or higher for approximately 2.6 seconds. Cause The sub/main thermistor is faulty. The engine controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the engine controller PCB.
Causes: The temperature of the main thermistor shows 20 deg C or below for 300 ms continuously after the temperature of the main thermistor exceeds 50 deg C at least once. Cause The main thermistor is faulty. The engine controller PCB is faulty. The connector is in poor contact. The harness is faulty.
Remedy: - Replace the fixing film unit. - Replace the engine controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.