Remedy: - Check the connector of the laser scanner unit, DC controller PCB. - Replace laser scanner unit - Replace DC controller PCB
Code: E100-0003
Description: Scanner unit, laser unit, BD abnormality
Causes: Black optical assembly failure. Cause: Laser scanner defect, DC controller PCB defect
Remedy: - Check the connector of the laser scanner unit, DC controller PCB. - Replace laser scanner unit - Replace DC controller PCB
Code: E110
Description: BD correction control failure
Causes: The machine does not change to the scanner ready status, after starting BD control. Cause: Laser scanner unit defect, DC controller PCB defect
Remedy: - Replace the laser scanner unit - Replace DC controller PCB
Code: E196
Description: DCON ROM abnormality
Causes: DC controller PCB ROM update failed.
Remedy: - Replace DC controller PCB
Code: E197-0000
Description: Engine communication error
Causes: Internal communication error
Remedy: - Replace DC controller PCB - Replace main controller PCB
Code: E198
Description: DC controller memory failure
Causes: DC controller memory failure. Cause: DC controller PCB defect
Remedy: - Replace DC controller PCB
Code: E747
Description: EEPROM error
Causes: EEPROM error. Cause: Main controller PCB defect
Remedy: - Replace main controller PCB
Code: E840
Description: Release mechanism abnormality
Causes: Mechanism does not reach home position (engaged) after home position control begins. Cause: Fixing drive assembly defect, fixing release cam defect