  • Code: E805-0003
  • Description: Fan failure
  • Causes: Controller fan failure detected The controller fan does not rotate because some kind of failure occurred in it.
  • Remedy: Replace the controller fan.
  • Code: E805-0006
  • Description: Fan failure
  • Causes: Power supply fan failure The fan did not rotate even when 12 seconds elapsed after the motor rotation start order was received.
  • Remedy: • Reconnect the connector J21 on the DC controller PCB and the connector J106 on the low-voltage power supply unit. • If the voltage between the connectors J21-2 and J25-2 on the DC controller PCB is changed from 0V to approximately 24V immediately after the printer is turned on, replace the power supply fan.
  • Code: E806-0001
  • Description: Delivery fan error
  • Causes: Delivery fan error
  • Remedy: • Check the connection of the connector. • Replace the fan. • Check the harness (check for disconnected/pinched harness)
  • Code: E808-0001
  • Description: Error in low voltage power supply
  • Causes: Low-voltage power supply failure
  • Remedy: Replace the Low-voltage power supply unit.
  • Code: E825-0000
  • Description: Drum phase control sensor failure warning
  • Causes: Yellow drum phase control sensor failure warning • A slit was not detected for 4 seconds after slit detection started. • An abnormal slit width was detected.
  • Remedy: • Check the YMC drum drive gear. • Replace the YMC drum HP sensor (PS13).
  • Code: E825-0001
  • Description: Drum phase control sensor failure warning
  • Causes: Magenta drum phase control sensor failure warning • A slit was not detected for 4 seconds after slit detection started. • An abnormal slit width was detected.
  • Remedy: • Check the YMC drum drive gear. • Replace the YMC drum HP sensor (PS13).
  • Code: E825-0002
  • Description: Drum phase control sensor failure warning
  • Causes: Cyan drum phase control sensor failure warning • A slit was not detected for 4 seconds after slit detection started. • An abnormal slit width was detected.
  • Remedy: • Check the YMC drum drive gear. • Replace the YMC drum HP sensor (PS13).
  • Code: E825-0003
  • Description: Drum phase control sensor failure warning
  • Causes: Black drum phase control sensor failure warning • A slit was not detected for 4 seconds after slit detection started. • An abnormal slit width was detected.
  • Remedy: • Check the Bk drum drive gear. • Replace the Bk drum HP sensor (PS12).