Các lỗi thường gặp

Code :
  • Code: E110 0000
  • Description: Laser Scanner error
  • Causes: The Laser Scanner Motor did not become ready although a specified period of time had passed.
  • Remedy: 1. Replace the Laser Scanner Unit. 2. Replace the DC Controller PCB.
  • Code: E196 0000
  • Description: DCON ROM error
  • Causes: The ROM of the DC Controller PCB failed to be updated.
  • Remedy: 1. Install the set of the controller firmware. 2. Replace the DC Controller PCB.
  • Code: E196 1000
  • Description: Main Controller PCB writing/reading error
  • Causes: Error in writing/reading of main program in the Main Controller PCB
  • Remedy: 1. Install the set of the controller firmware. 2. Replace the Main Controller PCB.
  • Code: E196 2000
  • Description: Main Controller PCB writing/reading error
  • Causes: Error in writing/reading of the setting values storage area in the Main Controller PCB
  • Remedy: 1. Install the set of the controller firmware. 2. Replace the Main Controller PCB.
  • Code: E198 0000
  • Description: DC Controller memory error
  • Causes: Error in the nonvolatile memory on the DC Controller
  • Remedy: Replace the DC Controller PCB.
  • Code: E202 0001
  • Description: CIS Unit HP error (outward)
  • Causes: The CIS Unit did not move to HP even it moved backward. Reader HP Sensor error, Reader Motor error, CIS Unit error
  • Remedy: 1. Replace the Reader HP Sensor. 2. Replace the Reader Motor. 3. Replace the CIS Unit. 4. Replace the Reader Unit.
  • Code: E202 0002
  • Description: CIS Unit HP error (homeward)
  • Causes: The CIS Unit did not move to HP even it moved forward. Reader HP Sensor error, Reader Motor error, CIS Unit error
  • Remedy: 1. Replace the Reader HP Sensor. 2. Replace the Reader Motor. 3. Replace the CIS Unit. 4. Replace the Reader Unit.
  • Code: E225 0001
  • Description: Light intensity of the CIS Unit below the reference level
  • Causes: When the light intensity is below the reference level at shading
  • Remedy: 1. Disconnect and then connect the Flexible Cable. 2. Replace the Flexible Cable. 3. Replace the CIS Unit. 4. Replace the Main Controller PCB (PCB2).