Description: Document End Sensor / Document Sensor
Causes: PS702/PS703
Remedy:
Code: E000 0000
Description: Error in temperature rising of Fixing Assembly
Causes: Temperature of the Fixing Assembly did not reach a certain temperature within the specified period of time.
Remedy: 1. Check the connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Code: E001 0000
Description: Abnormal high temperature of Fixing Assembly
Causes: It was detected that the temperature of the Fixing Assembly was abnormally high.
Remedy: 1. Check the connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.