Causes: Error in reader HP outward Failed to move to HP even when CIS unit moves backward.
Remedy: 1.Replace reader HP sensors 2.Replace reader motors 3.Replace reader units
Code: E202 0002
Description: Error in reader HP sensor
Causes: Error in reader HP homeward Failed to move to HP even when CIS unit moves forward.
Remedy: 1.Replace reader HP sensors 2.Replace reader motors 3.Replace reader units
Code: E246 0000
Description: System error
Causes: System error
Remedy: Contact to the sales companies.
Code: E247 0000
Description: System error
Causes: System error
Remedy: Contact to the sales companies.
Code: E248 0001
Description: Error in access to backup data for Reader (reading error at power-on)
Causes: The Reader-related adjustment values could not be read.
Remedy: 1. Clear the backup RAM of RCON. Execute COPIER>FUNCTION>CLEAR>RCON. 2. Enter all the values written on the service label in service mode again. 3. Turn OFF and then ON the main power.
Code: E350 0000
Description: System error
Causes: System error
Remedy: Contact to the sales companies.
Code: E351 0000
Description: System error
Causes: System error
Remedy: 1.Turn OFF and then ON the main power. 2.Replace main controller PCBs