Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon imageCLASS 3240

Code: E000

Description: The thermistor has an open circuit or a short circuit.
The heater has an open circuit.
The thermal fuse has blown.
The High-voltage power supply board has a fault.
The DCNT board has a fault.
Remedy: - Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the High-voltage power supply board.
- Replace the DCNT board.

Code: E100

Description: The scanner assembly has a fault.
Remedy: - Check the connector of the laser scanner assembly.
- Replace the laser scanner assembly.
- Replace the engine controller PCB.

Code: E198

Description: Flash ROM write error.
Remedy: - Turn the power OFF and then back ON.
- Replace the SCNT board.

Code: E225

Description: CIS lamp has a fault.
Remedy: - Turn the power OFF and then back ON.
- Replase the CIS unit.

Code: E674

Description: Modem error.
Remedy: - Turn the power OFF and then back ON.
- Replace the SCNT board.