Remedy: • Turn OFF and then ON the main power. If the error persists, obtain the following information and contact the department in charge of quality management. • Output STATUS PRINT/ P-PRINT. • Collect Sublog • Collect information on conditions to reproduce the error • Obtain user's print data (binary data)
Causes: Temperature of the Main Thermistor did not become the specified temperature although the specified time had passed.
Remedy: 1. Check the connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.
Causes: The Main Thermistor detected a temperature higher than the specified temperature.
Remedy: 1. Check the connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.
Causes: Error in either the Fixing Heater or the Fixing Motor
Remedy: 1. Check the connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Check the connection of the Fixing Motor. 3. Replace the Fixing Assembly. 4. Replace the Fixing Motor. 5. Replace the Fixing Power Supply Unit.
Remedy: 1. Check the connector between the DC Controller PCB and the Fixing Power Supply PCB. 2. Replace the Fixing Power Supply PCB. 3. Replace the DC Controller PCB.
Remedy: 1. Check the Cassette 1 Lifter Motor (dropout, gear tooth jump, etc.). 2. Check the connector between the Cassette 1 Lifter Motor and the DC Controller PCB. 3. Replace the Cassette 1 Lifter Motor. 4. Replace the DC Controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.