Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Check that the heater resistance measured between 1PIN and 2PIN of the cable (J101) on the DC Controller Board is in the following range. Replace the Fixing Assembly when the resistance value is abnormal. [1] 120 V machine - Heater resistance: 16.0 U ±7% [2] 230 V machines - Heater resistance: 53.8 U ±7% (2) Check the connection of connector (J101) on the DC Controller Board. (3) Check the connection of connector (J552) on DC Controller Board. (4) Replace the Fixing Assembly. (5) Replace the DC Controller Board.
Code: E003-0000
Description: Abnormal lowtemperature detection
Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Check that the heater resistance measured between 1PIN and 2PIN of the cable (J101) on the DC Controller Board is in the following range. Replace the Fixing Assembly when the resistance value is abnormal. [1] 120 V machine - Heater resistance: 16.0 U ±7% [2] 230 V machines - Heater resistance: 53.8 U ±7% (2) Check the connection of connector (J101) on the DC Controller Board. (3) Check the connection of connector (J552) on DC Controller Board. (4) Replace the Fixing Assembly. (5) Replace the DC Controller Board.
Code: E004-0000
Description: Fixing power supply drive circuit error
Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Replace the DC Controller Board. (2) Replace the Fixing Assembly.
Code: E100-0001
Description: Error detection on any of scanner motor, laser unit, and BD detection at scanner area.
Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Replace the Laser Scanner Unit. (2) Replace the DC Controller Board.
Code: E196-2000
Description: ROM read/write error (Error in storing each setting values for user mode / service mode / factory mode)
Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Update the set of the Controller Firmware (2) Replace the Main Controller Board.
Code: E202-0002
Description: Contact Sensor HP error, Failure in return
Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Check the connection of Flat Cable between Main Controller Board (J5) and Contact Sensor. (2) Replace the Flat Cable between Main Controller Board (J5) and Contact Sensor. (3) Replace the Contact Sensor. (4) Replace the Main Controller Board.
Code: E225-0001
Description: Light intensity of a lamp is less or equal to the criteria
Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Check the connection of Flat Cable between Main Controller Board (J5) and Contact Sensor. (2) Replace the Flat Cable between Main Controller Board (J5) and Contact Sensor. (3) Replace the Contact Sensor. (4) Replace the Main Controller Board.
Code: E301-0001
Description: Insufficient light intensity in shading
Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. (1) Check the connection of Flat Cable between Main Controller Board (J5) and Contact Sensor. (2) Replace the Flat Cable between Main Controller Board (J5) and Contact Sensor. (3) Replace the Contact Sensor. (4) Replace the Main Controller Board