Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon imageCLASS MF3010

Code: E000

Description: Startup failure
Remedy: (1) Check the connectors of the Fixing Assembly. (J101, J1011, J552 and J702)
(2) Replace the Fixing Assembly.
(3) Replace the Engine Controller PCB.

Code: E001

Description: Abnormal high temperature
Remedy: (1) Check the connectors of the Fixing Assembly. (J101, J1011, J552 and J702)
(2) Replace the Fixing Assembly.
(3) Replace the Engine Controller PCB.

Code: E003

Description: Abnormal low temperature
Remedy: (1) Check the connectors of the Fixing Assembly. (J101, J1011, J552 and J702)
(2) Replace the Fixing Assembly.
(3) Replace the Engine Controller PCB.

Code: E004

Description: Fixing heater drive circuit error (200V models only)
Remedy:

Code: E100

Description: Scanner area failure
Remedy: (1) Check the connectors of the Fixing Assembly. (J101, J1011, J552 and J702)
(2) Replace the Fixing Assembly.
(3) Replace the Engine Controller PCB.

Code: E196

Description: ROM read/write error (error in storing setting values in user mode/service mode/ factory mode)
Remedy: When the same error repeatedly occurs although the power is turned OFF and then ON for several times, execute the following remedies.
(1) Update the firmware of the Main Controller PCB.
(2) Replace the Main Controller PCB.

Code: E202

Description: CIS Unit home position detection error / homeward reading position error
Remedy: When the same error repeatedly occurs although the power is turned OFF and then ON for several times, execute the following remedies.
(1) Check the connection between the Main Controller PCB and the CIS Unit. (J2)
(2) Replace CIS Unit.
(3) Check the connection between the Main Controller PCB and the Reader Motor (M3). (J11)
(4) Replace the Reader Motor (M3).
(5) Replace the Main Controller PCB.

Code: E225

Description: Insufficient lamp light intensity (The light intensity is at the reference level or below.)
Remedy: When the same error repeatedly occurs although the power is turned OFF and then ON for several times, execute the following remedies.
(1) Check the connection between the Main Controller PCB and the CIS Unit. (J2)
(2) Replace CIS Unit.
(3) Replace the Main Controller PCB.