Description: Abnormally high temperature (detected by main thermistor)
The main thermistor detected an abnormally high temperature 235 deg C) during temperature control
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Description: Abnormally high temperature (detected by sub thermistor)
The sub thermistor detected an abnormally high temperature (300 deg C) during temperature control.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Description: Abnormally low temperature (detected by main thermistor)
After the temperature detected by the main thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Description: Abnormally low temperature (detected by sub thermistor)
After the temperature detected by the sub thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.