Các lỗi thường gặp

Code :
  • Code: E196-0001
  • Description: Image processor PCB failure
    Error on writing and readout ROM of image processor PCB (mainn ROM).
  • Remedy: - Putting the switch on/off of the power supply. - Replace the image processor PCB.
  • Code: E196-0002
  • Description: Image processor PCB failure
    Error on writing and readout ROM of image processor PCB (option ROM).
  • Remedy: - Putting the switch on/off of the power supply. - Replace the image processor PCB.
  • Code: E197-0000
  • Description: Printer engine communication error
    Erroneous communication between the DC controller PCB and image processor PCB was detected.
  • Remedy: - Check the connectors of the DC controller PCB and image processor PCB. - Replace the DC controller PCB for normal connection. - Replace the image processor PCB.
  • Code: E261-0000
  • Description: Zero-cross signal error
    If failed to detect zero-cross signal cycle of the power supply when initializing. When the input of the zero-signal failed continuously for three seconds while controlling the temperature adjustment.
  • Remedy: - Replace the power supply PCB. - Replace the DC controller PCB.
  • Code: E500-0001
  • Description: Finisher communication error
    Data communication could not be performed normally. It has been retried three times in vain.
  • Remedy: - Check the connectors of the finisher controller PCB and DC controller PCB for normal connection. - Replace the finisher controller PCB. - Replace the DC controller PCB.
  • Code: E520-0001
  • Description: - Offset motor or finisher controller PCB failure
    - Offset HP sensor failure
    - The offset motor was driven for 1000 ms in the HP sensor approach direction, but the offset HP sensor did not turn on.
  • Remedy: - Check the connector of the offset HP sensor. - Check the connector of the offset motor. - Replace the offset HP sensor. - Replace the offset motor. - Replace the finisher controller PCB.
  • Code: E520-0002
  • Description: - Offset motor or finisher controller PCB failure
    - Offset HP sensor failure
    - The offset motor was driven for 1000 ms in the HP sensor escape direction, but the offset HP sensor did not turn off.
  • Remedy: - Check the connector of the offset HP sensor. - Check the connector of the offset motor. - Replace the offset HP sensor. - Replace the offset motor. - Replace the finisher controller PCB.
  • Code: E531-0001
  • Description: - Staple unit failure
    - Staple HP sensor failure
    - Finisher controller PCB failure
    - The staple home position was not left when 400 ms have lapsed since start of staple operation.
  • Remedy: - Check the connector of the staple unit. - Replace the staple unit. - Replace the finisher controller PCB.