Description: Image processor PCB failure
Error on writing and readout ROM of image processor PCB (mainn ROM).
Remedy: - Putting the switch on/off of the power supply. - Replace the image processor PCB.
Code: E196-0002
Description: Image processor PCB failure
Error on writing and readout ROM of image processor PCB (option ROM).
Remedy: - Putting the switch on/off of the power supply. - Replace the image processor PCB.
Code: E197-0000
Description: Printer engine communication error
Erroneous communication between the DC controller PCB and image processor PCB was detected.
Remedy: - Check the connectors of the DC controller PCB and image processor PCB. - Replace the DC controller PCB for normal connection. - Replace the image processor PCB.
Code: E261-0000
Description: Zero-cross signal error
If failed to detect zero-cross signal cycle of the power supply when initializing. When the input of the zero-signal failed continuously for three seconds while controlling the temperature adjustment.
Remedy: - Replace the power supply PCB. - Replace the DC controller PCB.
Code: E500-0001
Description: Finisher communication error
Data communication could not be performed normally. It has been retried three times in vain.
Remedy: - Check the connectors of the finisher controller PCB and DC controller PCB for normal connection. - Replace the finisher controller PCB. - Replace the DC controller PCB.
Code: E520-0001
Description: - Offset motor or finisher controller PCB failure
- Offset HP sensor failure
- The offset motor was driven for 1000 ms in the HP sensor approach direction, but the offset HP sensor did not turn on.
Remedy: - Check the connector of the offset HP sensor. - Check the connector of the offset motor. - Replace the offset HP sensor. - Replace the offset motor. - Replace the finisher controller PCB.
Code: E520-0002
Description: - Offset motor or finisher controller PCB failure
- Offset HP sensor failure
- The offset motor was driven for 1000 ms in the HP sensor escape direction, but the offset HP sensor did not turn off.
Remedy: - Check the connector of the offset HP sensor. - Check the connector of the offset motor. - Replace the offset HP sensor. - Replace the offset motor. - Replace the finisher controller PCB.
Code: E531-0001
Description: - Staple unit failure
- Staple HP sensor failure
- Finisher controller PCB failure
- The staple home position was not left when 400 ms have lapsed since start of staple operation.
Remedy: - Check the connector of the staple unit. - Replace the staple unit. - Replace the finisher controller PCB.