Description: Abnormally low temperature (detected by main thermistor)
After the temperature detected by the main thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E003-0001
Description: Abnormally low temperature (detected by sub thermistor)
After the temperature detected by the sub thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E007-0000
Description: Fixing film sensor failure
The fixing film sensor is faulty.
Remedy: - Check the connector of the fixing film sensor. - Replace the fixing film sensor. - Replace the DC controller PCB.
Code: E010-0000
Description: Main motor failure
The main motor is faulty.
Remedy: - Check the connector of the main motor. - Replace the main motor. - Replace the DC controller PCB.
Code: E019-0000
Description: Waste toner full detection
The waste toner full state was detected.
Remedy: Replace the drum unit.
Code: E019-0001
Description: Waster toner full detection sensor is faulty.
The waste toner full state was detected continuously for five or more seconds while the main motor was turning.
Remedy: - Check the connector of the waster toner full sensor. - Replace the waste toner full sensor. - Replace the DC controller PCB.
Code: E052-0000
Description: Erroneous connection to duplex unit
Disconnection of the duplex unit was detected after power-on, detection of normal connection to the duplex unit, and start of communication.
Remedy: - Check the connectors of the duplex unit and DC controller PCB. - Replace the duplex controller PCB. - Replace the DC controller PCB.
Code: E100-0000
Description: BD detection PCB failure
The BD detection PCB is faulty.
Remedy: - Check the connector of the BD detection PCB. - Replace the laser scanner unit. - Replace the DC controller PCB.