Description: Error in the fixing assembly start-up
Causes: Insufficient temperature rise detected by thermistor even after applying bias to the heater
Remedy: 1.Check connectors of fixing assembly, DC controller PCB, fixing power supply unit, etc. 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs
Description: Abnormally high temperature detected in fixing assembly
Causes: Abnormally high temperature detected by main thermistor
Remedy: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCB
Description: Abnormally high temperature detected in fixing assembly (sub thermistor triggered)
Causes: Abnormally high temperature detected by sub thermistor (sub thermistor triggered)
Remedy: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs
Description: Abnormally low temperature detected in fixing assembly (sub thermistor triggered)
Causes: Temperature drop detected by sub thermistor after attaining the target temperature (sub thermistor triggered)
Remedy: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs