Causes: When 1 sec passed after energization of the heater, the detected temperature of the main thermistor is not 5 deg C or more (0 deg C at power on). Cause Disconnection of main thermistor, disconnection of fixing heater, error in DC controller PCB.
Remedy: - Check of the connector of the low-voltage power supply PCB - Replacement of fixing sleeve unit - Replacement of DC controller PCB
Description: Error in overheating of fixing assembly
Causes: The status where the detected temperature of the main thermistor is 225 deg C (approx. 0.84V equivalent) or more is detected for 0.5 continuous sec or more. Cause Error in main thermistor, error in DC controller PCB.
Remedy: - Check of the connector of the low-voltage power supply PCB - Replacement of fixing sleeve unit - Replacement of DC controller PCB
Description: Error in overheating of fixing assembly
Causes: The status where the detected temperature of the sub thermistor is 245 deg C (approx. 2.12V equivalent) or more is detected for 0.5 continuous sec or more. Cause Error in sub thermistor, error in DC controller PCB.
Remedy: - Check of the connector of the low-voltage power supply PCB - Replacement of fixing sleeve unit - Replacement of DC controller PCB
Description: Error in abnormally low temperature of fixing assembly
Causes: The status where the detected temperature of the main thermistor is 100 deg C (approx. 2.60V equivalent) or less is detected for 0.5 continuous sec or more. Cause Error in low-voltage power supply PCB, disconnection of main thermistor, error in DC controller PCB.
Remedy: - Replacement of low-voltage power supply PCB - Replacement of fixing sleeve unit - Replacement of DC controller PCB
Description: Error in abnormally low temperature of fixing assembly
Causes: The status where the detected temperature of the sub thermistor is less than 100 deg C (approx. 0.38V equivalent) is detected 0.5 continuous sec or more after energization of the heater. Cause Error in sub thermistor, error in DC controller PCB.
Remedy: - Check of the connector of the low-voltage power supply PCB - Replacement of fixing sleeve unit - Replacement of DC controller PCB
Causes: When 3.5 sec passed after activation of ETB motor, the cycle of ETB motor speed detection signal does not become its specified value. Cause Error in ETB motor, error in DC controller PCB.
Remedy: - Replacement of ETB motor - Replacement of DC controller PCB
Causes: After ETB motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more. Cause Error in ETB motor, error in DC controller PCB.
Remedy: - Replacement of ETB motor - Replacement of DC controller PCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.