Causes: Error in ITB/TOP sensor Cause Failure in ITB/TOP sensor, failure in DC controller PCB
Remedy: - Check the connectors of the ITB unit and DC controller PCB(J161,J160,J141) - Replace the ITB - Replace the DC controller PCB
Code: E078-0001
Description: Error in primary transfer disengagement.
Causes: Primary transfer disengagement mechanism did not work properly. Cause Disengagement mechanism error, ITB Tension Sensor error, Pickup Motor error, DC Controller PCB error
Remedy: - Check the disengagement mechanism. - Check the connectors of the ITB Tension Sensor, Pickup Motor and the DC Controller PCB (J167, J202, J160, J201, J140). - Replace the ITB Tension Sensor. - Replace the Pickup Motor. - Replace the DC Controller PCB.
Code: E100-0000
Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in yellow scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
Remedy: - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Code: E100-0001
Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in magenta scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
Remedy: - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Code: E100-0002
Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in cyan scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB
Remedy: - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Code: E100-0003
Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in black scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
Remedy: - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Code: E110-0002
Description: Pseudo BD correction error
Causes: Pseudo BD correction processing delay
Remedy: - Replace the laser scanner unit - Replace the DC controller PCB
Code: E194-0000
Description: Error in CPR sensor
Causes: If CPR sensor is judged error. Cause Soiling in density detection sensor, failure in density detection sensor, failure in DC controller PCB, failure in toner cartridge
Remedy: - Check the connector of DC controller PCB - Replace the ITB unit - Replace the DC controller PCB - Replace the toner cartridge