Description: VH leak error at rebooting (support number : 1478)
Causes: The printer does not recover by rebooting after VH leak error at starting up, cleaning, and print starting.
Remedy: 1 Perform [DIAGNOSIS > CR_SYSTEM_CHECK] to diagnose carriage system. No problem Go to 2. Abnormal • Problem in ACC. SENSOR CHECK or CR VIBRATIONCHECK Replace CARRIAGE UNIT. • Problem in LONG FFC CHECK or CRC value changes after turning the printer off and back on Replace FLEXIBLE CABLE UNIT. 2 Remove the print head and check the condition of print head contacting part. Proper condition Replace the print head. Improper condition Go to 3. 3 Clean the surface of the print head contacting part. (The waste cloth without a nap must be used.) The problem is resolved Complete. The problem is not resolved Go to 4. 4 Replace the print head. The problem is resolved Complete. The problem is not resolved Replace MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)
Description: Print head abnormal VH voltage error (support number : 4801)
Causes: VH voltage of the print head is detected.
Remedy: 1 Perform [DIAGNOSIS > CR_SYSTEM_CHECK] to diagnose carriage system. No problem Go to 2. Abnormal • Problem in ACC. SENSOR CHECK or CR VIBRATIONCHECK Replace CARRIAGE UNIT. • Problem in LONG FFC CHECK or CRC value changes after turning the printer off and back on Replace FLEXIBLE CABLE UNIT. 2 Remove the print head and check the condition of print head contacting part. Proper condition Replace the print head. Improper condition Go to 3. 3 Clean the surface of the print head contacting part. (The waste cloth without a nap must be used.) The problem is resolved Complete. The problem is not resolved Go to 4. 4 Replace the print head. The problem is resolved Complete. The problem is not resolved Replace MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)
Description: VHTR leak error at print head replacement (support number : 1477)
Causes: VHTR leak is detected at print head replacement.
Remedy: 1 Perform [DIAGNOSIS > CR_SYSTEM_CHECK] to diagnose carriage system. No problem Go to 2. Abnormal • Problem in ACC. SENSOR CHECK or CR VIBRATIONCHECK Replace CARRIAGE UNIT. • Problem in LONG FFC CHECK or CRC value changes after turning the printer off and back on Replace FLEXIBLE CABLE UNIT. 2 Remove the print head and check the condition of print head contacting part. Proper condition Replace the print head. Improper condition Go to 3. 3 Clean the surface of the print head contacting part. (The waste cloth without a nap must be used.) The problem is resolved Complete. The problem is not resolved Go to 4. 4 Replace the print head. The problem is resolved Complete. The problem is not resolved Replace MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)
Description: VHTR leak error at rebooting (support number : 1478)
Causes: The printer does not recover by rebooting after VHTR leak error at starting up, cleaning, and print starting.
Remedy: 1 Perform [DIAGNOSIS > CR_SYSTEM_CHECK] to diagnose carriage system. No problem Go to 2. Abnormal • Problem in ACC. SENSOR CHECK or CR VIBRATIONCHECK Replace CARRIAGE UNIT. • Problem in LONG FFC CHECK or CRC value changes after turning the printer off and back on Replace FLEXIBLE CABLE UNIT. 2 Remove the print head and check the condition of print head contacting part. Proper condition Replace the print head. Improper condition Go to 3. 3 Clean the surface of the print head contacting part. (The waste cloth without a nap must be used.) The problem is resolved Complete. The problem is not resolved Go to 4. 4 Replace the print head. The problem is resolved Complete. The problem is not resolved Replace MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)
Description: Print head abnormal VHTR voltage error (support number : 4801)
Causes: Abnormal VHTR voltage of the print head is detected.
Remedy: 1 Perform [DIAGNOSIS > CR_SYSTEM_CHECK] to diagnose carriage system. No problem Go to 2. Abnormal • Problem in ACC. SENSOR CHECK or CR VIBRATIONCHECK Replace CARRIAGE UNIT. • Problem in LONG FFC CHECK or CRC value changes after turning the printer off and back on Replace FLEXIBLE CABLE UNIT. 2 Remove the print head and check the condition of print head contacting part. Proper condition Replace the print head. Improper condition Go to 3. 3 Clean the surface of the print head contacting part. (The waste cloth without a nap must be used.) The problem is resolved Complete. The problem is not resolved Go to 4. 4 Replace the print head. The problem is resolved Complete. The problem is not resolved Replace MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)
Description: Print head VSH leak error at print head replacement (support number : 1477)
Causes: VSH leak is detected at print head replacement.
Remedy: 1 Perform [DIAGNOSIS > CR_SYSTEM_CHECK] to diagnose carriage system. No problem Go to 2. Abnormal • Problem in ACC. SENSOR CHECK or CR VIBRATIONCHECK Replace CARRIAGE UNIT. • Problem in LONG FFC CHECK or CRC value changes after turning the printer off and back on Replace FLEXIBLE CABLE UNIT. 2 Remove the print head and check the condition of print head contacting part. Proper condition Replace the print head. Improper condition Go to 3. 3 Clean the surface of the print head contacting part. (The waste cloth without a nap must be used.) The problem is resolved Complete. The problem is not resolved Go to 4. 4 Replace the print head. The problem is resolved Complete. The problem is not resolved Replace MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.