Các lỗi thường gặp

Code :
  • Code: E198-401D
  • Description: RTC low battery error A battery error has been detected while initializing the RTC at startup.
  • Remedy: 1. Restart the printer in service mode. 2. Check the RTC battery. 3. Replace the main controller PCB.
  • Code: E198-401E
  • Description: RTC clock stop The RTC has been detected idle while initializing the RTC at startup.
  • Remedy: 1. Restart the printer in service mode. 2. Replace the main controller PCB.
  • Code: E199-404B
  • Description: Temperature/humidity sensor error When temperature 0 and humidity 0% are detected, the detection mechanism is considered failed and an error message is displayed.
  • Remedy: 1. Restart the printer in service mode to clear the error. 2. Identify the firmware version and update the firmware to the last release if it is earlier than Ver.1.31 (firmware defect). 3. Remove and reinsert the temperature/humidity sensor PCB connector 4. Replace the temperature/humidity sensor PCB.
  • Code: E602-401A
  • Description: HDD failure Failed to read and write to and from the HDD.
  • Remedy: 1. Restart in service mode. 2. Remove and install HDD 3. Replace HDD. Switch on service mode after the replacement.
  • Code: E602-401B
  • Description: Poor HDD connection The HDD and the HDD controller are not indefinable.
  • Remedy: 1. Restart in service mode. 2. Remove and install HDD 3. Replace HDD. Switch on service4. Replace HDD controller or the main controller PCB. Restart after the replacement.
  • Code: E602-405A
  • Description: Incorrect capacity HDD model is connected.
  • Remedy: Replace HDD
  • Code: E602-405B
  • Description: Mismatched HDD model is connected.
  • Remedy: Replace HDD
  • Code: x-4042
  • Description: Unknown file. Check file format. Turn off printer, wait a while, then turn it on again. MIT data transfer failure Failed to write MIT data on its transmission.
  • Remedy: 1. Execute "Initialize Paper Type" from the system settings. (Note: All paper information will be reset to its factory defaults and additional Paper deleted.) 2. Upgrade the firmware in download mode. 3. Replace the main controller PCB.
‹ First  < 2 3 4 5 6 > 