Code: 2F53

Display: Hardware error. 03130031-2F53. Turn off printer,wait, then turn on again.
Description: Supply valve motor error of the left ink tank. Drove supply valve motor. The movement was not detected.
Remedy: iPF8400/9400 Series 1. Replace the left ink tank unit. 2. Replace the main controller PCB.

Code: 2F54

Display: Hardware error. 03130031-2F54. Turn off printer,wait, then turn on again.
Description: Supply valve motor error of the right ink tank. Drove supply valve motor. The movement was not detected.
Remedy: iPF8400/9400 Series 1. Replace the right ink tank unit. 2. Replace the main controller PCB.

Code: 2F60

Display: Spectrophotometer Unit not connected. Turn off power and attach Spectrophotometer Unit.
Description: Spectrophotometer unit won't return signals.
Remedy: 1. Install spectrophotometer unit. 2. Replace signal line. 3. Replace connection. 4. Replace spectrophotometer unit PCB.

Code: 2F61

Display: Hardware error 038A0002-2F61 Turn off printer, wait a while, then turn it on again.
Description: UART communication error. (Data transfer volume in consistency, checksum error etc.)
Remedy: 1. Replace signal line. 2. Replace connection. 3. Replace spectrophotometer unit PCB

Code: 2F62

Display: Hardware error 038A0002-2F62 Turn off printer, wait a while, then turn it on again.
Description: When transmitting specified pulses to spectrophotometer carriage motor, the spectrophotometer carriage unit won't respond to spectrophotometer carriage HP sensor.
Remedy: 1. Replace spectrophotometer unit PCB. 2. Replace lines around spectrophotometer carriage unit. 3. Replace spectrophotometer carriage motor.

Code: 2F63

Display: Hardware error 038A0002-2F63 Turn off printer, wait a while, then turn it on again.
Description: The spectrophotometer up-down unit upper detection sensor won't respond when a predefined pulse is sent to the spectrophotometer up-down unit motor.
Remedy: 1. Replace spectrophotometer updown unit motor. 2. Replace spectrophotometer updown unit upper detection sensor. 3. Re-install delivery guide. 4. Replace the spectrophotometer unit PCB.

Code: 2F65

Display: Hardware error 038A0002-2F65 Turn off printer, wait a while, then turn it on again.
Description: When a predefined pulse is sent to the spectrophotometer up-down unit motor, the spectrophotometer up-down unit lower detection sensor in spectrophotometer unit won't respond.
Remedy: 1. Replace spectrophotometer updown unit motor. 2. Replace spectrophotometer updown unit lower detection sensor. 3. Re-install delivery guide. 4. Replace the spectrophotometer unit PCB.

Code: 2F66

Display: Hardware error 038A0002-2F66 Turn off printer, wait a while, then turn it on again.
Description: Media dry fan won't return signals.
Remedy: 1. Replace fan 2. Replace signal lines 3. Replace the spectrophotometer unit PCB.