Các lỗi thường gặp

Code :
  • Code: 1037
  • Display: GARO W1233
  • Description: (Setup mode) Required item missing The exit parameter is missing in the EnterGAROMode command and the UniversalExitLanguage command used in Setup mode.
  • Remedy: 1. Identify the model. 2. If the error has occurred with RIP, try with the printer driver. 3. Try in an alternative environment (I/ F, PC).
  • Code: 1038
  • Display: GARO W1234
  • Description: (Setup mode)Data out of bounds A character string that is not defined as an environmental variable has been detected. An unknown environmental variable has been detected. A character string that is not defined as an environmental variable value has been detected. The value of an unknown environmental variable has been detected.
  • Remedy: 1. Identify the model. 2. If the error has occurred with RIP, try with the printer driver. 3. Try in an alternative environment (I/ F, PC).
  • Code: 1039
  • Display: GARO W1235
  • Description: (Setup mode) Other warning A character string other than the @PJL prefix has been detected while the analysis module was idle.
  • Remedy: 1. Identify the model. 2. If the error has occurred with RIP, try with the printer driver. 3. Try in an alternative environment (I/ F, PC).
  • Code: 103A
  • Display: GARO W1226
  • Description: (Image mode) Image processing table error No image processing table is being transmitted, a required image processing table is unavailable, or an image processing table contains a value out of bounds.
  • Remedy: 1. Retransmit. 2. Check with a different interface choice. 3. Try by printing other data. 4. With RIP, print from the print driver. Supplement: If this error occurs, the print result would appear blank.
  • Code: 1040
  • Display: GL2: W0501 The memory is full.
  • Description: HP/GL2 error; Insufficient memory capacity The size of drawing data exceeds the processing capacity.
  • Remedy: 1. Reduce the size of rendering data. 2. Replace with HP RTL data for manipulation with On The Fly*. *: On The Fly: The method to transmit data in sequence from paper. The software that generates HP-GL/2 data has this option to specify. Select this option to save the memory usage of the printer.
  • Code: 1041
  • Display: GL2: W0502 The parameter is out of range.
  • Description: HP/GL2 error; invalid parameter Data having an invalid number of types of parameters that follow the command has been detected.
  • Remedy: Verify the data and fix it.
  • Code: 1043
  • Display: GL2: W0504 This command is not supported.
  • Description: HP/GL2 error; Invalid command A command that is not defined in HP-GL/2 or HP RTL is included.
  • Remedy: Verify the data and fix it.
  • Code: 1047
  • Display: GL2: W0903 The memory is full.
  • Description: HP/GL2 error; replot buffer overflow Data storage buffers have run short.
  • Remedy: 1. Reduce the size of rendering data. 2. Replace with HP RTL data for manipulation with On The Fly*. *: On The Fly: The method to transmit data in sequence from paper. The software that generates HP-GL/2 data has this option to specify. Select this option to save the memory usage of the printer.